LAMP CAPPING CEMENTS

Incandescent and Halogen High Efficiency Lamps

These Cements are designed to maintain the integrity of the bond between the glass and the metal cap over a wide range of temperatures, wattages and lamp life. They typically contain phenolic resin, shellacs, silicone resin and a range of inorganic fillers with carefully selected particle size distributions.

These products are used for Incandescent light bulbs and Halogen incandescent lamps.

CodeProduct
K12/MGrade for linear fluorescent lamps and standard incandescent up to 100 watts with 1000 hours life. Ideal where customers wish to use one grade for both fluorescent and incandescent.Safety SheetData Sheet
K35/MIncandescent grade up to 100 watts with 1000 hours life, with modified processing characteristics.Safety SheetData Sheet
K44/MBBasic grade for fluorescent lamps with 8000-10000 hours life.Safety SheetData Sheet
K64/MIncandescent grade up to 150 watts with 2500 hours lamp life. Can also be used for decorative and reflector lamps.Safety SheetData Sheet
K66/MIncandescent grade up to 150 watts with 2500 hour lamp life.Safety SheetData Sheet
K99/MHigh performance Grade for incandescent and HEI lamps of up to 500 watts with a life of up to 2500 hours at a working temperature of 210°C.Safety SheetData Sheet
K112/MGrade for linear fluorescent lamps with additional humidity resistance, standard incandescent and HEI lamps up to 100 watts with 1000 hours life. Ideal where customers wish to use one grade for both fluorescent and incandescent.Safety SheetData Sheet
K112Grade for linear fluorescent lamps with additional humidity resistance , standard incandescent and HEI lamps up to 100 watts with 1000 hours life. Safety SheetData Sheet
K190/MHigh temperature grade for incandescent lamps up to 500 watts and high intensity discharge lamps up to 1000 watts with working temperatures up to 300°C.Safety SheetData Sheet
K6000/MGrade for standard incandescent lamps up to and including 100 watts with 1500 hours lamp life.Safety SheetData Sheet
SJE522Grade for incandescent lamps required to stand 2500 hours at 210°C. Safety SheetData Sheet
K17000/MGrade with improved humidity for linear fluorescent lamps and standard incandescent lamps up to and including 100 watts with 1500 hours lamp life.Safety SheetData Sheet
P18/MGrade for incandescent lamps of upto 500 watts with a life of upto 2500 hours at a working temperature of 210°C. Safety SheetData Sheet
P190/MHigh temperature grade for incandescent lamps upto 500 watts and high intensity discharge lamps upto 1000 watts with working temperatures upto 300°C. Safety SheetData Sheet
P641/MGrade for incandescent and HEI lamps of up to 150 watts with a life of up to 2500 hours. Safety SheetData Sheet
P966/MHigh performance grade for incandescent lamps required to stand 2500 hours at 210°C. Safety SheetData Sheet
P6000/MBasic grade for linear fluorescent lamps, standard incandescent and HEI lamps, up to and including 100 watts, with 1500 hours lamp life. Safety SheetData Sheet
P16000/MBasic grade for linear fluorescent lamps, standard incandescent and HEI lamps up to and including 75 watts with 1500 hours lamp life. Safety SheetData Sheet
P17000/MBasic grade with improved humidity for linear fluorescent lamps, standard incandescent and HEI lamps up to and including 75 watts with 1500 hours lamp life. Safety SheetData Sheet
 
Fluorescent and Compact Fluorescent Lamps
These cements are designed to maintain the integrity of the bond between the glass and cap (typically metal or plastic) for the life of the lamp that can be between 3000hr and 30000hr. These cements contain a range of thermoset and thermoplastic materials in conjunction with specialised compounds designed to protect the adhesive bond from ingress of moisture or humidity.

These are used for tubular fluorescent and compact fluorescent lamps, the most widely used lamp in the world.

CodeProduct
K11/MBasic grade for linear fluorescent lamps with 6000hr lamp life.Safety SheetData Sheet
K111/MBasic grade with improved humidity resistance for linear fluorescent lamps. Safety SheetData Sheet
K12/MGrade for linear fluorescent lamps and standard incandescent up to 100 watts with 1000 hours life. Ideal where customers wish to use one grade for both fluorescent and incandescent.Safety SheetData Sheet
K112/MGrade for linear fluorescent lamps with additional humidity resistance, standard incandescent and HEI lamps up to 100 watts with 1000 hours life. Ideal where customers wish to use one grade for both fluorescent and incandescent.Safety SheetData Sheet
K16/SGrade for linear fluorescent lamps compatible with both ethanol and trioxane based mixing systems.Safety SheetData Sheet
K76/MHigh performance grade for linear fluorescent lamps. Can also be used for incandescent lamps up to 1500 hours at 210°C.Safety SheetData Sheet
K112Grade for linear fluorescent lamps with additional humidity resistance , standard incandescent and HEI lamps up to 100 watts with 1000 hours life. Safety SheetData Sheet
K130TGrade suitable for linear fluorescent lamps containing low levels of mercury.Safety SheetData Sheet
K132TEco cement grade suitable for linear fluorescent lamps compatible with both ethanol and trioxane based mixing systems. When tubes are disposed of at end of life, this cement reduces the mercury levels available for leaching from landfill sites.Safety SheetData Sheet
K134TEco cement grade suitable for linear fluorescent lamps containing higher levels of Mercury, compatible with both ethanol and trioxane based mixing systems. When tubes are disposed of at end of life, this cement reduces the Mercury levels available for leaching from landfill sites.Safety SheetData Sheet
K163/MHigh performance grade for use in linear fluorescent lamps giving high torque strength and moisture resistance.Safety SheetData Sheet
K165/MHigh performance grade for compact fluorescent lamps.Safety SheetData Sheet
P11/MOGrade for linear fluorescent lamps giving high torque strength and moisture resistance. Safety SheetData Sheet
P12/MGrade for linear fluorescent lamps and standard incandescent up to 100 watts with 1000 hours life. Safety SheetData Sheet
K116/MHigh performance grade for compact fluorescent lamps. Safety SheetData Sheet
P163/MHigh performance grade for use in linear fluorescent lamps Safety SheetData Sheet
P165/MHigh performance grade for compact fluorescent lamps. Safety SheetData Sheet
P6000/MBasic grade for linear fluorescent lamps, standard incandescent and HEI lamps, up to and including 100 watts, with 1500 hours lamp life. Safety SheetData Sheet
P16000/MBasic grade for linear fluorescent lamps, standard incandescent and HEI lamps up to and including 75 watts with 1500 hours lamp life. Safety SheetData Sheet
P17000/MBasic grade with improved humidity for linear fluorescent lamps, standard incandescent and HEI lamps up to and including 75 watts with 1500 hours lamp life. Safety SheetData Sheet
High Pressure & High Intensity (HID) Discharge Lamps
Our HIGH PRESSURE DISCHARGE CEMENTS are designed to maintain the integrity of the bond between the glass and cap for the life of the lamp at wattages between and 35W and 150W and operating temperatures up to 250°C, these cements contain high levels of silicone resin in addition to standard thermoset and thermoplastic ingredients.

Typical applications - Metal Halide, Sodium and Mercury Vapour Lamps.

The HIGH INTENSITY DISCHARGE (HID) CEMENTS are designed to maintain the integrity of the bond between the glass and cap for the life of the lamp at wattages up to 1000W and operating temperatures up to 300°C, these cements contain high levels of silicone resin and bespoke ingredients in addition to standard thermoset and thermoplastic ingredients.

Typical applications - HID Lamps to light large outdoor areas.

CodeProduct
K18/MGrade for incandescent lamps of up to 500 watts with a life of up to 2500 hours at a working temperature of 210°C.Safety SheetData Sheet
K66/MHigh performance grade for incandescent lamps required to stand 2500 hours at 210°C. Can also be used for HEI, decorative and reflector lamps.Safety SheetData Sheet
K99/MGrade for incandescent and HEI lamps of up to 500 watts with a life of up to 2500 hours at a working temperature of 210°C.Safety SheetData Sheet
K190/MHigh temperature grade for incandescent lamps up to 500 watts and high intensity discharge lamps up to 1000 watts with working temperatures up to 300°C.Safety SheetData Sheet
K192Grade suitable for high wattage lamps, with a life of up to 12000 hours at 350°C.Safety SheetData Sheet
P966/MHigh performance grade for incandescent lamps required to stand 2500 hours at 210°C. Can also be used for HEI, decorative and reflector lamps.Safety SheetData Sheet
Automotive & Street Lighting Lamps

Cements with a high whiteness index to improve the reflective quality of the lamp.

These are typically used for Headlights, brake lights, indicators and SOX low pressure sodium lamps.

CodeProduct
K20Basic semi-white grade with modified rheological properties for special, incandescent and automotive lamps.Safety SheetData Sheet
SJE501FHigh performance grade specifically developed for sox lampsSafety SheetData Sheet

Not sure what you need?

Through our programme of continuous investment and product development, we are seen by
many as a global centre of excellence for Lamp Capping Cements.

To help us choose the right organic cement for you, we require the following information:

Lamp type and operating temperature?
Speed of cure required?
Proposed method of cure?
Operating Environment?
Materials of construction?
Method of application of paste to component?
Proposed storage conditions for cement?

READY TO GET IN TOUCH WITH US?